counter
keep count based on input events
Description
Outputs the current count of event messages constrained to a specified range. Can be set to count up, down, or up-then-down.
Inlets
input [bang]
When any event message (bang or number) is received in the left inlet, add the
value to the current count.direction [number]
Set Direction: 0 = Up, 1 = Down, 2 = UpDownresetnext [number, bang]
A number received in the middle inlet will be output the next time the left inlet receives an event message. Note that this value can be outside the current limits of the counter.
resetnow [number, bang]
A number received in the right-middle inlet sets the internal state of the counter and is immediately sent out the left outlet.
maximum [number]
Sets the maximum count value.
Outlets
output [number]
Outputs the current count value whenever the left inlet receives an event message (or when the middle-right inlet receives a number).
underflow [bang, number]
The left-middle outlet sends a number or bang (depending on the
attribute) any time the minimum count is reached. Note this only applies when using 1 (down) or 2 (up/down).overflow [bang, number]
The right-middle outlet sends a number or bang (depending on the
attribute) any time the maximum count ( ) is reached. Note this only applies when using 0 (up) or 2 (up/down).carry [number]
Tracks the total number of times that counter has reached the counting limit. If using
, reaching both the minimum and the maximum values will add to the carry count.Fixed Attributes
These attributes must be set in the object box and determine the behavior of the object at runtime.
inc [number] (default: 1)
Determines the amount that will be added to the count each time a new event message is received in the left inlet.
Dynamic Attributes
These attributes can be modified in the code during execution using the set object
carryflag [enum] (default: numeric)
Set underflow/overflow output type
Possible values:
0 = 'numeric'
1 = 'bang'
direction [number]
Set Direction: 0 = Up, 1 = Down, 2 = UpDown
input [bang]
When any event message (bang or number) is received in the left inlet, add the
value to the current count.maximum [number]
Sets the maximum count value.
minimum [number] (default: 0)
Set the minimum value for the counting range.
resetnext [number, bang]
A number received in the middle inlet will be output the next time the left inlet receives an event message. Note that this value can be outside the current limits of the counter.
resetnow [number, bang]
A number received in the right-middle inlet sets the internal state of the counter and is immediately sent out the left outlet.
See Also
Name | Description |
---|---|
counter | |
accum | Additive accumulator |
counter~ | counter~ |
tempo | tempo |